Model · EAK Series High-Performance Power Line Filters
EAK Series High-Performance Power Line Filters
The EAK series high-performance power line filters offer excellent attenuation at low frequencies and effectively suppress both common-mode and differential-mode interference. With high current capacity and rated currents ranging from 50 to 1,000 A, they are suitable for applications requiring clean power, such as data processing systems, telecommunications systems, medical equipment, and industrial control devices. The filters are rated for 440/250 VAC and operate at 50/60 Hz. They withstand dielectric test voltages of up to 1,500 VDC (line-to-line) and 2,250 VDC (line-to-ground), and have a climatic category of 40/085/21. Models are available for different rated currents: 50EAK1, 80EAK1, 100EAK1, 150EAK1, 300EAK3, 400EAK3, 600EAK3, 800EAK3, and 1000EAK5. Each model has different grounding capacitance and discharge resistance specifications to support applications at various power levels.
Overview
The EAK series high-performance power line filters offer excellent attenuation at low frequencies and effectively suppress both common-mode and differential-mode interference. With high current capacity and rated currents ranging from 50 to 1,000 A, they are suitable for applications requiring clean power, such as data processing systems, telecommunications systems, medical equipment, and industrial control devices. The filters are rated for 440/250 VAC and operate at 50/60 Hz. They withstand dielectric test voltages of up to 1,500 VDC (line-to-line) and 2,250 VDC (line-to-ground), and have a climatic category of 40/085/21. Models are available for different rated currents: 50EAK1, 80EAK1, 100EAK1, 150EAK1, 300EAK3, 400EAK3, 600EAK3, 800EAK3, and 1000EAK5. Each model has different grounding capacitance and discharge resistance specifications to support applications at various power levels.
Product category: Low-voltage electrical equipment / Filters / Power line filters
Models & specifications
| Model / Name | Discharge resistance kohm | Ground capacitance pf | Rated current a | Ground capacitance uf |
|---|---|---|---|---|
| 50EAK1 50EAK1 Power Line Filter (50 A) | 440 | 94 | 50 | |
| 80EAK1 80EAK1 Power Line Filter (80 A) | 440 | 200 | 80 | |
| 100EAK1 100EAK1 Power Line Filter (100 A) | 440 | 200 | 100 | |
| 150EAK1 150EAK1 Power Line Filter (150 A) | 440 | 200 | 150 | |
| 300EAK3 300EAK3 Power Line Filter (300 A) | 660/330 | 300 | 2.4 | |
| 400EAK3 400EAK3 Power Line Filter (400 A) | 660/330 | 400 | 2.4 | |
| 600EAK3 600EAK3 Power Line Filter (600 A) | 660/330 | 600 | 2.4 | |
| 800EAK3 800EAK3 Power Line Filter (800 A) | 660/330 | 800 | 3.05 | |
| 1000EAK5 1000EAK5 Power Line Filter (1,000 A) | 660/330 | 1000 | 3.05 |