Pneumatic solenoid valve not switching: How to check whether the correct valve function was selected

If a solenoid valve does not switch as expected when energized, first check whether the correct valve function was selected. A directional control valve is needed to control the direction of air supply to the two chambers of a cylinder; a line on/off valve cannot perform this function.

Line on/off valves start or stop the flow of media

For example, the 0927 series is a two-position, two-way, normally closed, pilot-operated diaphragm solenoid valve designed for line on/off control. If the task is to change the direction of air supply to the two cylinder chambers, select a valve with a directional control function.

Use a directional control valve to reverse cylinder movement

Pneumatic directional control valves come in different body sizes. For example, the SY series includes sizes such as SY3000, SY5000 and SY7000. Selection should be based on the cylinder's air supply direction control requirements.