Troubleshooting Ball Screw Axial Play: What Other Clearances Should You Check?

When troubleshooting axial play in a ball screw, also check the nut flange connection and the clearance in the nut assembly to avoid confusing problems in different parts of the drive system. Both areas warrant attention when backlash is excessive or positioning accuracy is inconsistent.

Check the connection between the nut flange and the table

Prolonged reciprocating motion can loosen the screws securing the nut flange, creating play at the connection. Before checking the nut assembly clearance, inspect the flange attachment to the table to avoid mistaking a loose connection for a nut assembly problem.

Adjust double-nut assembly clearance according to its design

In a double-nut assembly that uses adjustment shims, changing the shim thickness shifts the two nuts axially, eliminating clearance and creating preload. The adjustment method depends on the nut assembly design.

Check single-nut assemblies for raceway wear

For a single-nut assembly with non-adjustable clearance, check the screw and nut raceways for wear if play develops. If wear is severe, the entire screw and nut assembly must be replaced. If wear is minor, fitting larger-diameter balls may be considered, but this is a complex repair requiring considerable technical expertise.