Control Valves · Reduced-Wiring Valve Manifold

3A/4A Series Air-Controlled Valves
The 3A/4A series consists of pneumatic directional control valves, including 3A 3-port, 2-position valves; 4A 5-port, 2-position valves; 3H 3-port, 3-position valves; 4H 5-port, 3-position valves; and 3R/4R series manually operated valves. Valve bodies are available in the 100, 200, 300, 400, 1000/2000/3000/4000, and 10000/20000/30000/40000 series sizes, with various air control methods, port sizes, and initial states, such as NO (normally open). They are suitable for directional switching and pilot control in pneumatic circuits on automated equipment. Model numbers combine the series code, series size, air control method, port size, initial state, and other fields. Confirm both the port size and control method when selecting a model.

4A Series
The 4A series of graphic symbols includes hundreds of models, ranging from 4A10 to 4A910. Each model number begins with 4A, followed by three digits indicating the size series; the two digits after the hyphen indicate the interface or function code. The series is available in a range of specifications, such as 4A10-06, 4A10-08, 4A10-10, and 4A10-15. It covers sizes from 10 mm to 910 mm, with interface codes including 06, 08, 10, and 15, and is used to represent and apply graphic symbols in industrial automation systems.

4H Series Flat Valves
The 4H series flat valve is a multi-position, five-way directional control valve with a flat-plate design, intended for pneumatic control systems. The ordering code consists of the series code, series designation, number of positions, port size, and configuration code. Series designations 2–4 correspond to valve bodies with different numbers of positions. The available position configurations are single-solenoid, two-position (10) and single-solenoid, three-position (30). Port sizes are G1/8 (06), G1/4 (08), G3/8 (10), and G1/2 (15). Configurations include spring-return (blank) and detent (L).

XQ Series Quick Exhaust Valve

4F210 Series Foot Valve
2-position, 5-way foot valve.

KG Series Hand Slide Valve
Reverse air inlet configuration available on request.

3R/4R Series Hand-Operated Valves

FV320/420 Series Foot Valves
4A400 Series Air-Operated Valves
5-port 2-position, 5-port 3-position.
F1 Series Valve Island

4HV Series Hand Rotary Valve

F1/F2/F3 Series Integrated Wiring Valve Manifolds
F1/F2/F3 series integrated wiring valve manifolds (also known as valve islands or solenoid valve manifolds) allow multiple solenoid valves to be mounted on a common base with centralized piping and wiring. This significantly reduces the number of tubes and wiring harnesses, saves installation space, and simplifies maintenance. Products are supplied by number of positions (stations), and overall length L varies linearly with the number of positions: the F1 model is 115mm long with 4 positions, increases by 16mm for each additional position, and reaches 243mm at the maximum of 12 positions. F2 model length is calculated as L=number of positions×K+80, where K is the solenoid valve pitch (generally the standard manifold pitch +1mm); it can be expanded to 24 positions. The F3 model is custom-developed, and manifold dimensions vary with the solenoid valve used. For example, when fitted with 4V210 solenoid valves, it is 124mm long with 4 positions, increases by 23mm for each additional position, and is 354mm long with 14 positions. A 10-position integrated wiring manifold for the SY5120 series is also available. When selecting a product, confirm the solenoid valve model, number of positions, port size, and mounting hole locations.

F2 Series Valve Manifold
The F2 series valve manifold (solenoid valve manifold block) mounts multiple solenoid valves together with a common air supply and centralized wiring, enabling integrated piping in pneumatic control systems. The F2 is a custom-developed manifold with an overall length calculated as L = nK + 80, where n is the number of stations and K is the solenoid valve spacing (typically the standard manifold spacing plus 1mm). Common configurations have 4~14 stations and can be customized to suit the number of valves and non-standard spacing, so dimensions vary depending on the solenoid valves used. The same family also includes the F1 fixed-spacing valve manifold (for the SY5120 centralized-wiring valve manifold, 4~12 stations, overall length 115~243mm, pitch 16mm) and the F3 valve manifold (compatible with 4V210 solenoid valves, 4~14 stations, overall length 124~354mm, pitch 23mm). Key specifications include the number of stations, solenoid valve spacing K, overall length L, compatible valve type, air supply method, and wiring method.

F3 Series Valve Manifold
The F3 series is a custom-developed pneumatic solenoid valve manifold designed to mount multiple solenoid valves together, reducing piping and wiring. The verified dimensions for use with 4V210 solenoid valves are as follows: for 4~14 valve stations, the corresponding lengths are L=124, 147, 170, 193, 216, 239, 262, 285, 308, 331, and 354 mm, increasing by approximately 23 mm per additional station. As manifold dimensions vary with the solenoid valve, confirm the valve model, number of stations, ports, and mounting method when selecting a product. F3 is a custom product and cannot be ordered as a standard stock item.

HBWD Pneumatic Sequence Valve
The HBWD series pneumatic sequence valve controls the operating sequence of actuators in pneumatic circuits. Adjust the delay-time screw to set a delay of 1–10 seconds. It uses dry air as the working medium, with a maximum operating pressure of 0.6 MPa, a minimum operating pressure of 0.2 MPa, a proof pressure of 1.5 MPa, a minimum passage area of 4.0 mm², and an operating temperature range of 0–70°C. The delay is adjustable, making the valve suitable for automation equipment requiring time-based control. Note that the initial operating delay may be longer. To extend the delay, connect an auxiliary air tank to the T port to increase capacity. Circuit conditions may cause the pressure on the inlet side to drop. Wait at least 5 seconds before restoring the air supply after it has been shut off. When using multiple valves, series connection is recommended. The product is compact and lightweight, weighing just 0.2 kg.

JM Series 2-Position, 3-Way Pneumatic Valve
The JM Series comprises 2-position, 3-way directional control valves. The working medium is air filtered to 40 microns, and the operating temperature range is 0–60°C. Four models are available: JM-05, JM-06, JM-06A, and JM-07. They are suitable for switching air circuits in automation control systems.

TW/DB Series Universal and Bottom Plug-in Valve Manifolds
TW/DB series universal and bottom plug-in valve manifolds provide centralized mounting for multiple solenoid valves. The universal type uses a conventional manifold base with an optional wiring module, offering versatility at a low cost. The bottom plug-in type features a custom base plate and an attractive, integrated all-aluminum alloy design. Compatible with solenoid valves including FESTO VUVG-L10/LK10 and VUVG-L14/LK14, SMC SY3□20/SY5□20/SY7□20, AirTAC 4V100M/4V200M, and CKD 4GD1/4GD2. Rated voltage: DC24V. Available with single- or double-solenoid control and 04-24 stations. Single-solenoid configurations support up to 24 stations and double-solenoid configurations up to 12 stations; A+B≤24 must also be satisfied.

SY5120 Centralized Wiring Valve Manifold
The SY5120 centralized wiring valve manifold (manifold block) provides centralized mounting for SY series, 4V210, and other solenoid valves, allowing multiple valves to share air supply, exhaust, wiring, and piping. The product is available in configurations based on station count: The F1 is a standard manifold with 4~12 stations and an overall length L of 115~243 mm; L increases by 16 mm for each additional station. The F2 length is calculated as L=station count×K+80, where K is the solenoid valve spacing (typically standard manifold spacing+1 mm); it can accommodate up to 24 stations. The F3 is a custom-developed manifold specifically for 4V210 valves, with 4~14 stations corresponding to L 124~354 mm. Manifold dimensions vary by solenoid valve, so confirm the valve model, station count, and spacing when selecting a product.