How to size a machine vision light controller: Check voltage, then calculate channel and total loads

First, match the output voltage to the lights' requirements

First, enter the rated voltage and current of each light, then select a controller with an output voltage that meets the lights' requirements. For example, the AC-24V24W-2T has an output voltage of 8~24V and adjusts brightness by varying the voltage. Its 100~240V AC power input is a separate specification and must not be confused with the output voltage supplied to the lights.

Check current for each channel, then calculate power

Calculate power from each light's rated voltage and current: Power (W) = Voltage (V) × Current (A). The current drawn by each light must also be within the controller's per-channel limit. For the controller above, the maximum output current per channel is 1A. A 24V, 0.5A light draws 12W, and its current is within the channel limit.

Add the power of all channels operating simultaneously

For multichannel controllers, also check the total output power; do not simply add the allowable power for each channel. The controller above has two channels and a total output power of 24W. If each channel is connected to one 24V, 0.5A light, the total draw is 24W when both operate simultaneously, reaching the total power limit. If each channel is connected to one 24V, 1A light, the total is 48W, exceeding the total power limit even though neither channel exceeds 1A.

Once power requirements are met, check dimming and triggering

After checking voltage, current, and total power, compare dimming methods and trigger signals based on operating conditions. For example, the AC-24V24W-2T uses voltage modulation, accepts a trigger input of 5~24V, and has a trigger delay of less than 150μs. If external triggering is required, ensure the equipment's trigger signal matches the controller's input requirements.