Air Filters

HAD402 Series Automatic Drain

HAD402 Series Automatic Drain

When installing the drain hose, use a hose with an inner diameter of at least Φ10 mm and a length no greater than 5 m. Do not allow the hose to bend upward. The compressor power must be greater than 3.7 kW.

AF/BF Series Air Filters

AF/BF Series Air Filters

AF/BF series air filters are used for air preparation in pneumatic systems. They are generally installed at the inlet of an air preparation unit to remove moisture, oil mist, and solid dust from compressed air, protecting downstream pneumatic components such as solenoid valves and cylinders. Two series are available by port size: the AF series has small ports, with 1500 (1/8") and 2000 (1/4") sizes; the BF series has larger ports, with 3000 (3/8") and 4000 (1/2") sizes. Drain options are differential-pressure drain (no designation) and manual drain (M); the BF series also offers automatic drain (A). Filtration ratings are 40μm (no designation) and 5μm (W). Thread options are PT (no designation), G (G), and NPT (T). The model number is formed by directly joining the series code, port size, drain type, filtration rating, and thread code in that order. For example, AF2000MW denotes the AF series, a 1/4" port, manual drain, and 5μm filtration.

AF Series Air Filters

AF Series Air Filters

AF Series air filters remove water and dust from compressed air. They are often combined with AFM Series mist separators to form modular air preparation filter assemblies. The AF30-A listed in the catalog can be fitted to an inline filter assembly and installed independently or on a panel using the B310-L upper bracket and Y30, Y30L or Y40T spacers. Related pages also provide the set pressure ranges, supply voltages and connection specifications for compatible ITV electro-pneumatic proportional valves and IR precision regulators, making it easier to select components for a complete air preparation system.

AF Series Air Filters

AF Series Air Filters

AF Series air filters are air preparation components for pneumatic systems, designed to remove moisture and contaminants from compressed air. Available in five sizes—AF1000, AF2000, AF3000, AF4000 and AF5000—they cover port sizes from M5 to 1 inch, with Rc and NPT threads also available. Rated flow is approximately 110–7000 L/min. Some sizes can be fitted with an automatic drain (models B240/B340/B440/B540/B640) for automatic water removal. Flow is tested at a supply pressure of 0.7MPa and a set pressure of 0.5MPa. Suitable for air purification and moisture removal in a wide range of pneumatic circuits, these filters serve as the filtration unit in a standard three-piece air preparation assembly.

GF Series Water Separators

GF Series Water Separators

GF series water separators remove moisture and filter solid particles from compressed air lines. A copper flow-guiding structure induces rotation in the airflow, improving liquid separation and reliably filtering solid particles. The separators feature low pressure drop, high water separation efficiency and a large bowl capacity. Filtration ratings of 5μm and 40μm are available, with manual, differential-pressure or automatic drainage. An optional mounting bracket is also available. The body is aluminum alloy, the O-ring is NBR, the flow guide is high-viscosity POM, and the filter element is sintered bronze particles (40μm). The filter bowl is aluminum alloy on the GF600 and PC on other models. The level gauge protective cover is SPCC, the level gauge sealing gasket is fluororubber, and the level gauge inner cover is PC.

GFC Series Air Filters

GFC Series Air Filters

GFC series air filters provide air preparation for pneumatic systems, with quick, secure connections for easy installation and use. They offer stable, repeatable pressure regulation and efficiently remove moisture and solid particles from compressed air. Three drain options are available: manual, differential pressure and automatic. Filtration ratings are 40μm or 5μm, with optional square or round pressure gauges and a reverse-flow valve. Port sizes range from PT1/8 to PT1, operating pressure is 0.15~0.9MPa, and operating temperature is -20~70℃. Filter bowl capacity is 10CC/40CC and drain capacity is 25CC/75CC. The filters can be combined with GFR series indicating components and GL series lubricators to form a three-piece air preparation unit.

LF Series Air Filters

LF Series Air Filters

The LF series comprises air filters in the SNS air preparation range. They use a sintered filter element with a water separator to remove moisture, oil mist and solid particles from compressed air, supplying clean air to downstream pneumatic components. Three frame sizes are available: MINI (small), MIDI (medium) and MAXI (large), with G1/8, G1/4, G3/8, G1/2, G3/4 and G1 port threads. Filtration ratings are 40μm and 5M (5μm). Drain options include a manual drain valve (maximum working pressure 16bar) and a type A automatic drain valve (working pressure 1.5~12bar). Maximum condensate capacity is 22ml, the operating temperature is 0~60℃, and installation must be vertical within ±5°. Pipe or bracket mounting is supported. The working medium is lubricated or unlubricated compressed air, and the filter bowl and body are made primarily of plastic and die-cast aluminum.

QSL Series Air Filter and Water Separator

QSL Series Air Filter and Water Separator

The QSL series air filter and water separator cleans compressed air by removing moisture and solid particles. It is typically installed upstream in pneumatic systems. Ambient temperature: 5-60℃; nominal inlet pressure: 0.63MPa; filtration rating: 50-70μm; water separation efficiency: ≥85%. Connection threads include G1/4, G3/8, G1/2, G3/4 and G1, with models ranging from QSL-8 to QSL-50. The pressure drop–airflow chart shows airflow rates at different inlet pressures. Overall dimensions are labeled A, D, D1, D2, L0, L1 and L.

QFLH Series Air Filters

QFLH Series Air Filters

QFLH series air filters are air preparation components manufactured by SNS Automation (Ningbo) Group Co., Ltd. Installed in compressed air lines, they remove moisture, oil mist, and solid particles to protect downstream pneumatic equipment such as cylinders and solenoid valves. The series includes eight models from QFLH-08 to QFLH-50, with port sizes from G1/4 to G2 to meet the needs of both low- and high-flow air systems. Filter elements are available with filtration ratings of 20μm or 40μm. The working pressure range is 0.15~4.0MPa, the maximum input pressure is 4MPa, the operating temperature range is 5~80℃, and the working fluid is air. The housings have standard threaded ports, with each model's port size matched to its flow capacity. They are suitable for pre-filtration and point-of-use protection in general industrial compressed air systems.

QTYH Series Air Filters

QTYH Series Air Filters

QTYH series air filters clean the air supply in pneumatic systems by removing solid particles and contaminants from compressed air, protecting downstream components such as solenoid valves and pneumatic cylinders. The series is available in eight sizes: 08, 10, 15, 20, 25, 32, 40 and 50, with corresponding port sizes G1/4, G3/8, G1/2, G3/4, G1, G11/4, G11/2 and G2. They cover applications from low-flow air lines serving individual machines to high-flow main air lines. The working medium is air, and filter elements are available in 20μm and 40μm grades for general filtration. The working pressure range is 0.15-4.0MPa, the maximum inlet pressure is 4MPa, and the operating temperature range is 5-80℃. The model code consists of QTYH followed by a two-digit size code, with each size code corresponding to a port size. Select a model to match the pipe diameter and required flow rate.

QFRH Series Air Filters

QFRH Series Air Filters

QFRH series air filters are air preparation components that remove solid particles and condensate from compressed air, providing clean air to downstream pneumatic components such as cylinders and solenoid valves. The series comprises 7 nominal sizes: QFRH-10, QFRH-15, QFRH-20, QFRH-25, QFRH-32, QFRH-40 and QFRH-50, with corresponding port sizes of G1/4, G3/8, G1/2, G3/4, G1, G1-1/4 and G1-1/2 (larger sizes up to G2). Filter elements are available in 20μm or 40μm ratings to suit downstream cleanliness requirements. The operating pressure range is 0.05~3.5MPa, the maximum inlet pressure is 4MPa, and the operating temperature range is -25~+80℃. The working medium is air. The bowl has a protective guard (PA69) and a round bent mounting bracket for easy attachment to equipment panels or piping. These filters are widely used for upstream air purification and pre-filtration on automated production lines in packaging, assembly, machine tools, automotive, electronics and other industries.